Imaging of Emitting Mercury Atom Spatial Distributions in a Capillary Discharge Lamp by Using Tomography Approach
IEEE Transactions on Plasma Science 2008
Natalia Denisova, Gita Rēvalde, Atis Skudra, Egils Bogans

A tomographic reconstruction of emitting mercury atom spatial profiles in a capillary lamp with an inner diameter of 1 mm has been made for the first time in this work. Measurements of emission intensity have been performed for the capillary lamp in xenon-mercury mixture in dependence on the operation position. Intensities were measured for the 546.1-nm Hg line for vertically and horizontally operated lamps.


DOI
10.1109/TPS.2008.926967

Denisova, N., Rēvalde, G., Skudra, A., Bogans, E. Imaging of Emitting Mercury Atom Spatial Distributions in a Capillary Discharge Lamp by Using Tomography Approach. IEEE Transactions on Plasma Science, 2008, Vol.36, No.4, Part 1, 1188.-1189.lpp. ISSN 0093-3813. Pieejams: doi:10.1109/TPS.2008.926967

Publikācijas valoda
English (en)
RTU Zinātniskā bibliotēka.
E-pasts: uzzinas@rtu.lv; Tālr: +371 28399196