Multipolar Double Fed Induction Generator with Overturned Rotor
Proceedings of the EPE Wind Energy Chapter 1st Seminar (EPE-WECS 2008) 2008
Leonīds Ribickis, Guntis Diļevs, Nikolajs Levins, Vladislavs Pugačevs

This paper concerns the design and practical application of the multipolar induction generator which can be applied to small power directly driven wind generators (1 - 30 kW). All the windings of this generator are placed on the stator. The overturned rotor is tooth-like without windings on it. The stator is placed inside the rotor. This construction helps to reduce the weight of the generator for about 15-17% comparing with conventional design.


Atslēgas vārdi
Double fed, induction generator, wind energy
DOI
10.1109/EPEWECS.2008.4497319
Hipersaite
http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=4497319

Ribickis, L., Diļevs, G., Levins, N., Pugačevs, V. Multipolar Double Fed Induction Generator with Overturned Rotor. No: Proceedings of the EPE Wind Energy Chapter 1st Seminar (EPE-WECS 2008), Nīderlande, Delft, 27.-28. marts, 2008. Piscataway: IEEE, 2008, 1.-6.lpp. ISBN 9789075815122.

Publikācijas valoda
English (en)
RTU Zinātniskā bibliotēka.
E-pasts: uzzinas@rtu.lv; Tālr: +371 28399196