Electrochemical Drinking Water Disinfection with Tio2-X Ceramic Electrodes at Flow Conditions
Key Engineering Materials 2017
Viktorija Deņisova, Linda Mežule, Tālis Juhna, Jurijs Ozoliņš

Electrochemical disinfection device EDI-001 equipped with titanium oxide (TiO2-x) ceramic electrodes was tested as a system for direct treatment of drinking water at flow conditions. Laboratory experiments were conducted to estimate the disinfection efficiency and main system parameters. Escherichia coli was selected as the model microorganism. The results have shown that contaminated tap water was completely disinfected within 15 minutes by using EDI-001.


Atslēgas vārdi
Electrochemical disinfection, Titanium oxide, Drinking water, Escherichia coli
DOI
10.4028/www.scientific.net/KEM.721.133
Hipersaite
http://www.scientific.net/KEM.721.133

Deņisova, V., Mežule, L., Juhna, T., Ozoliņš, J. Electrochemical Drinking Water Disinfection with Tio2-X Ceramic Electrodes at Flow Conditions. No: Key Engineering Materials, Latvija, Rīga, 3.-4. novembris, 2016. Switzerland: Trans Tech Publications, 2017, 133.-137.lpp. ISSN 1013-9826. e-ISSN 1662-9795. Pieejams: doi:10.4028/www.scientific.net/KEM.721.133

Publikācijas valoda
English (en)
RTU Zinātniskā bibliotēka.
E-pasts: uzzinas@rtu.lv; Tālr: +371 28399196