Bone Loss around Dental Implants 5 Years after Implantation of Biphasic Calcium Phosphate (HAp/βTCP) Granules
Journal of Healthcare Engineering 2018
Vadims Kļimecs, Aleksandrs Grišuļonoks, Ilze Šalma, Laura Neimane, Jānis Ločs, Eva Šauriņa, Andrejs Skaģers

Biphasic calcium phosphate ceramic granules (0.5-1.0 mm) with a hydroxyapatite and β-tricalcium phosphate ratio of 90/10 were used. Biphasic calcium phosphate ceramic granules produced in the Riga Technical University, Riga Rudolph Cimdins Biomaterials Innovation and Development Centre, were used for filling the bone loss on 18 patients with peri-implantitis. After 5 years at the minimum, clinical and 3D cone-beam computed tomography control was done. Clinical situation confirmed good stability of implants without any signs of inflammation around. Radiodensity of the previous gap and alveolar bone horizontally from middle point of dental implants showed similar radiodensity as in normal alveolar bone.


Atslēgas vārdi
calcium phosphate, hydroxyapatite
DOI
10.1155/2018/4804902
Hipersaite
https://www.hindawi.com/journals/jhe/2018/4804902/

Kļimecs, V., Grišuļonoks, A., Šalma, I., Neimane, L., Ločs, J., Šauriņa, E., Skaģers, A. Bone Loss around Dental Implants 5 Years after Implantation of Biphasic Calcium Phosphate (HAp/βTCP) Granules. Journal of Healthcare Engineering, 2018, Vol.2018, 4804902.-4804902.lpp. ISSN 2040-2295. e-ISSN 2040-2309. Pieejams: doi:10.1155/2018/4804902