Centrifugal Pumps Uncoupled Shafts Laser Alignment and Its Influence on Vibration Level
9th International Conference on Vibrations in Rotating Machinery: Conference Proceedings 2008
Dmitrijs Ļitvinovs

In this article the analysis of laser shaft alignment method practical application for the uncoupled shafts of centrifugal pumping unit is conducted and given recommendations for shaft alignment maximal exactness providing of the uncoupled shafts. The analysis of vibration level (vibration velocity) dependence from alignment exactness is also resulted.


Atslēgas vārdi
Gear coupling, angular backlash, vibration velocity

Ļitvinovs, D. Centrifugal Pumps Uncoupled Shafts Laser Alignment and Its Influence on Vibration Level. No: 9th International Conference on Vibrations in Rotating Machinery: Conference Proceedings, Lielbritānija, Exeter, 9.-11. septembris, 2008. Exeter: Chandos Publishing (Oxford) Limited, 2008, 489.-495.lpp.

Publikācijas valoda
English (en)
RTU Zinātniskā bibliotēka.
E-pasts: uzzinas@rtu.lv; Tālr: +371 28399196