Determination of Heat Source Intensity as per Temperature Measurements inside a Body under Transient Process
Proceedings of the International Conference on Mathematical Models for Engineering Science (MMES'10)
2010
Ilmārs Iltiņš,
Marija Iltiņa
There is a method described in the article that allows calculating intensity of a heat source by using temperature measurements inside a body. A function of heat source intensity is defined as Fourier series.
Atslēgas vārdi
heat source, temperature, Fourier series
Hipersaite
http://dl.acm.org/citation.cfm?id=1965690
Iltiņš, I., Iltiņa, M. Determination of Heat Source Intensity as per Temperature Measurements inside a Body under Transient Process. No: Proceedings of the International Conference on Mathematical Models for Engineering Science (MMES'10), Spānija, Puerto De La Cruz, 30. Nov-2. Dec., 2010. Stevens Point: World Scientific and Engineering Academy and Society (WSEAS), 2010, 99.-100.lpp. ISBN 978-960-474-252-3.